I-Large Flux Reverse Osmosis ( RO ) I-Membrane TFC-3213-1000G iwumkhiqizo omusha, Umsebenzi wethu kanye nenhloso yebhizinisi kungaba "Ukufeza njalo izidingo zethu zomthengi".Sizohlinzeka ngekhwalithi ephezulu kakhulu, cishe intengo yokuthengisa encintisana kakhulu nomkhakha, kumthengi ngamunye omusha nophelelwe yisikhathi kuyilapho sisebenzisa izinsiza ezingcono kakhulu zochwepheshe eziluhlaza.
ZIFIHLETMI-Commercial Membrane iklelisa amabhrendi ahamba phambili e-China phakathi kwemboni ye-RO membrane.I-RO Membraneiwine ukwethenjwa kwamakhasimende amaningi ngokuphakela amanzi ahlanzekile athembekile eminyakeni eyi-10.Ulwelwesi ngalunye lwenziwe ngeshidi elithuthukisiwe le-HID elihlolisiswe ngaphambili futhi lidlula ezinqubweni eziqinile zokwenza kanye nokuhlolwa kwekhwalithi yasendlini nokuhlolwa ngaphambi kokulethwa.I-HID Membrane iqinisekiswe yi-SGS & China Jiangsu Sanitation Bureau ehlanganisa izici zolwelwesi lwamanzi okuphuza.
Imodeli No. | Okuncane.UsawotiUkwaliwa (%) | Usawoti OzinzileUkwenqatshwa(%) | I-Permeate FlowLinganisa(gpd) | I-TestTemp. | Ingcindezi Yokuhlola | Hlola Amanzi TDS |
TFC-3012-200 | 95 | 97 | 200 | 25℃ | awu 65psi | 500ppm |
TFC-3012-300 | 95 | 97 | 300 | 25℃ | awu 65psi | 500ppm |
TFC-3012-400 | 95 | 97 | 400 | 25℃ | awu 80psi | 500ppm |
TFC-3013-400 | 95 | 97 | 400 | 25℃ | 100psi | 500ppm |
TFC-3012-500 | 94 | 96 | 500 | 25℃ | 100psi | 500ppm |
TFC-3213-600 | 94 | 96 | 600 | 25℃ | 100psi | 500ppm |
TFC-3213-800 | 94 | 96 | 800 | 25℃ | 100psi | 500ppm |
TFC-3213-1000 | 94 | 96 | 1000 | 25℃ | 100psi | 500ppm |
1. Izinga lokugeleza kwe-Permeate kanye nokwenqatshwa kukasawoti kusekelwe ezimweni zokuhlola: 25℃, PH 7.5, 20% ukutakula.
2. Ukwenqatshwa kukasawoti ozinzile ngokuvamile kufinyelelwa phakathi kwamahora angu-24-48 okusetshenziswa okuqhubekayo, kuye ngezici zamanzi okuphakelayo nezimo zokusebenza.
Imodeli No. | Ubuningi Izinga Lokushisa Lokusebenza | Ubuningi Ingcindezi Yokusebenza | Okuphakelayo Amanzi Ububanzi be-PH, ukusebenza okuqhubekayo | Okuphakelayo okuphezulu Ukuqunjelwa Kwamanzi | Ubuningi Okuphakelayo Amanzi SDI | I-Chlorine Ukubekezelelana |
TFC-3012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3012-300 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3012-400 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3013-400 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3012-500 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3213-600 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3213-800 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
AmaMembrane e-HID RO asetshenziswa kakhulu emanzini ahlanzekile kakhulu, acubungula amanzi ahlanzekile, amanzi ombhoshongo wokupholisa, amanzi abhayela, amanzi ahlanzekile, kuyo yonke imboni ye-elekthronikhi, imboni ye-optoelectronic, ukukhiqizwa kwemishini, imboni yamakhemikhali emihle, imboni yezokwelapha, ukudla neziphuzo. , i-surface coating, nezinye izimboni eziningi.