We have by far the most highly developed manufacturing equipment, experienced and qualified engineers and workers, regarded high-quality handle systems along with a friendly qualified revenue team pre/after-sales support for Reverse Osmosis Membrane With Housing, ro membrane with housing, To make every client satisfied with us and achieve win-win success, we will continue to try our best to serve and satisfy you! Sincerely looking forward to cooperating with more overseas customers based on mutual benefits and great future business. Thank you.
HIDTM 1812 RO membrane with housing ranks the best brands in China among RO membrane industry. It has won the trust of thousands of families for feeding the reliable purified water over 10 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.
Model | TFC-1810-50 | TFC-1810-75 | TFC-1810-100 | TFC-2012-125 | TFC-2012-150 | TFC-2012- 200 | |
TFC-1812-50 | TFC-1812-75 | TFC-2012-100 | |||||
Perfor-mance | Stable Desalination % | 97 | 97 | 97 | 97 | 97 | 97 |
Min. Desalination % | 96 | 96 | 96 | 96 | 96 | 96 | |
Mean Permeable Flow GPD (L/d) | 50 (204) | 75 (281) | 100 (380) | 125 (478) | 150 (567.75) | 200(760) | |
Active Film Area ft2(m2) | 3.5 (0.32) | 4.2 (0.38) | 5.0 (0.46) | 5.0 (0.50) | 6.0 (0.8) | 10.33 (0.96) | |
Test Conditions | Pressure | 65psi (0.45Mpa) | |||||
Water Temp. | 25℃ | ||||||
Concentration(NaCl) | 500ppm | ||||||
Water PH | 6.5 to 7.5 | ||||||
Recovery Rate % | 15 | ||||||
Operating Conditions | Max. Operating Pressure | 200psi (2.0Mpa) | |||||
Max. Feed Water Temp. | 45℃ | ||||||
Max. Feed Water Silt Density Index (SDI) | 5 | ||||||
Feed Water Chlorine Tolerance | < 0.1 mg/l | ||||||
Feed Water PH Range, Continuous Operation | 3 to 10 | ||||||
Feed Water PH Range, Short-Term Cleaning | 2 to 11 | ||||||
Max. Pressure Drop of Single Membrane | 10psi (0.07Mpa) |
NOTE: The produced water amount listed in the table is an average value, compared with the standard value, the difference of the minimum amount of water produced by a single membrane does not exceed ± 15%.
Model No. | Maximum Operating Temperature |
Maximum Operating Pressure |
Feed Water PH Range, continuous operation |
Maximum Feed Water Turbidity |
Maximum Feed Water SDI |
Chlorine Tolerance |
TFC-1812-50 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-1812-75 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-100 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-125 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-150 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
We have by far the most highly developed manufacturing equipment, experienced and qualified engineers and workers, regarded high-quality handle systems along with a friendly qualified revenue team pre/after-sales support for 1812 Reverse Osmosis Membrane With Housing for Water Treatment, Our highly specialized process eliminates the component failure and offers our customers unvarying quality, allowing us to control cost, plan capacity and maintain consistent on-time delivery.