Opulenta nostra experientia ac considerata officia, in multis emptoribus internationalibus ementibus locuples adhibitus fuimus pro manufacturer membranae RO Element/ habitationi/pressionis, exspectationes, incepta consociationes et socios undique in universo mundo ad nos gratissime gratissime adeundi. et quaerere cooperationem ad rationes mutuas affirmativas.
Cum opulenta experientia et considerata officia, pro multis emptoribus internationalibus certae rei adhibiti sumusRo Element, omnes operarii in officinis, thesauris, et officio contendunt pro uno communi fine ad meliorem qualitatem et servitium praestandum.Negotium reale est ut rem vincat.Plura subsidia clientibus velimus liberare.Welcome to all nice buyers to communicate the details of our items with us!
HIDTMMembrana commercialis notas optimas in Sinis inter RO membranam industriam collocat.RO elementumFiduciam plurium clientium lucrata est alendis certa aqua mundata per X annos.Quaelibet membrana e HID evoluta & prae explorata scheda facta est, et per strictas processus faciendas tum in domo qualitatum inspectionis & probationis ante traditionem pergit.HID Membrana per SGS & Sinis Jiangsu Sanitationem hendrerit wrt elementa membranula aquam bibens certificata est.
Exemplar No. | Min.SalRejectio (%) | Confirmatur SalisRejectio(%) | Permeare ORate (gpd) | TestTemp. | Test Pressura | Test aqua TDS |
TFC-3012-200 | 95 | 97 | 200 | 25℃ | 65psi | 500ppm |
TFC-3012-300 | 95 | 97 | 300 | 25℃ | 65psi | 500ppm |
TFC-3012-400 | 95 | 97 | 400 | 25℃ | 80psi | 500ppm |
TFC-3013-400 | 95 | 97 | 400 | 25℃ | 100psi | 500ppm |
TFC-3012-500 | 94 | 96 | 500 | 25℃ | 100psi | 500ppm |
TFC-3213-600 | 94 | 96 | 600 | 25℃ | 100psi | 500ppm |
TFC-3213-800 | 94 | 96 | 800 | 25℃ | 100psi | 500ppm |
1. Permeate fluxus rate et salis rejectio nititur conditionibus probativis: 25℃, PH 7.5, 20% recuperatio.
2. Reiectio salis stabilita plerumque fit intra 24-48 horas continui usus, secundum qualitates feed aquae et condiciones operandi.
Exemplar No. | Maximum Operating Temperature | Maximum Operans Pressura | Pasce aquam PH Range, continua operatio | Maximum Feed Aquae Turbiditas | Maximum Aquam pasce SDI | Chlorine tolerantia |
TFC-3012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3012-300 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3012-400 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3013-400 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3012-500 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3213-600 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-3213-800 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
HID RO Membranae late adhibentur in aqua ultra-pura, processu aquae purae, aqua turris refrigerantis, aquae ferventis copia, aqua pura, per electronicarum industriam, industriam optoelectronic, fabricam machinam, industriam chemicam denique, pharmaceuticam medicinam, cibum et potum industriam. Superficies superficiei et multae aliae industriae.