Our company puts emphasis on the administration, the introduction of talented staff, along with the construction of employees building, seeking hard to boost the standard and liability consciousness of staff members. Our business successfully attained IS9001 Certification and European CE Certification of Factory Customized Supplier of 2012-100 GPD RO Membrane for Water Treatment, Our service concept is honesty, aggressive, realistic, and innovation. Together with your assistance, we’ll mature much better.
Our company puts emphasis on the administration, the introduction of talented staff, along with the construction of employees building, seeking hard to boost the standard and liability consciousness of staff members. Our business successfully attained IS9001 Certification and European CE Certification of 100gpd RO Membrane, We are committed to meet all your needs and solve any technical problems you may encounter with your industrial components. Our exceptional goods and vast knowledge of technology makes us the preferred choice for our customers.
HIDTM Residential Membrane ranks the best brands in China among the RO membrane industry. Reverse Osmosis (RO) Membrane 100 GPD has won the trust of thousands of families for feeding the reliable purified water over 10 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.
Model | TFC-1810-50 | TFC-1810-75 | TFC-1810-100 | TFC-2012-125 | TFC-2012-150 | TFC-2012- 200 | |
TFC-1812-50 | TFC-1812-75 | TFC-2012-100 | |||||
Perfor-mance | Stable Desalination % | 97 | 97 | 97 | 97 | 97 | 97 |
Min. Desalination % | 96 | 96 | 96 | 96 | 96 | 96 | |
Mean Permeable Flow GPD (L/d) | 50 (204) | 75 (281) | 100 (380) | 125 (478) | 150 (567.75) | 200(760) | |
Active Film Area ft2(m2) | 3.5 (0.32) | 4.2 (0.38) | 5.0 (0.46) | 5.0 (0.50) | 6.0 (0.8) | 10.33 (0.96) | |
Test Conditions | Pressure | 65psi (0.45Mpa) | |||||
Water Temp. | 25℃ | ||||||
Concentration(NaCl) | 500ppm | ||||||
Water PH | 6.5 to 7.5 | ||||||
Recovery Rate % | 15 | ||||||
Operating Conditions | Max. Operating Pressure | 200psi (2.0Mpa) | |||||
Max. Feed Water Temp. | 45℃ | ||||||
Max. Feed Water Silt Density Index (SDI) | 5 | ||||||
Feed Water Chlorine Tolerance | < 0.1 mg/l | ||||||
Feed Water PH Range, Continuous Operation | 3 to 10 | ||||||
Feed Water PH Range, Short-Term Cleaning | 2 to 11 | ||||||
Max. Pressure Drop of Single Membrane | 10psi (0.07Mpa) |
NOTE: The produced water amount listed in the table is an average value, compared with the standard value, the difference of the minimum amount of water produced by a single membrane does not exceed ± 15%.
Model No. | Maximum Operating Temperature |
Maximum Operating Pressure |
Feed Water PH Range, continuous operation |
Maximum Feed Water Turbidity |
Maximum Feed Water SDI |
Chlorine Tolerance |
TFC-1812-50 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-1812-75 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-100 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-125 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-150 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |