We depend on sturdy technical force and continually create sophisticated technologies to fulfill the demand of Hid Water Purifier Filter 50gpd Membrane Osmosis Reverse, If possible, make sure you send your necessities with a detailed list including the style/item and quantity you require. We'll then mail our greatest selling prices to you.
We depend on sturdy technical force and continually create sophisticated technologies to fulfill the demand of Membrane Osmosis Reverse, We believe with our consistently excellent service you can get the best performance and cost the least products from us for a long term. We commit to supply better services and create more value for all our customers. Hope we can create a better future together.
HIDTM Residential Membrane ranks the best brands in China among the RO membrane industry. Membrane Osmosis Reverse has won the trust of thousands of families for feeding the reliable purified water over 10 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.
Model | TFC-1810-50 | TFC-1810-75 | TFC-1810-100 | TFC-2012-125 | TFC-2012-150 | TFC-2012- 200 | |
TFC-1812-50 | TFC-1812-75 | TFC-2012-100 | |||||
Perfor-mance | Stable Desalination % | 97 | 97 | 97 | 97 | 97 | 97 |
Min. Desalination % | 96 | 96 | 96 | 96 | 96 | 96 | |
Mean Permeable Flow GPD (L/d) | 50 (204) | 75 (281) | 100 (380) | 125 (478) | 150 (567.75) | 200(760) | |
Active Film Area ft2(m2) | 3.5 (0.32) | 4.2 (0.38) | 5.0 (0.46) | 5.0 (0.50) | 6.0 (0.8) | 10.33 (0.96) | |
Test Conditions | Pressure | 65psi (0.45Mpa) | |||||
Water Temp. | 25℃ | ||||||
Concentration(NaCl) | 500ppm | ||||||
Water PH | 6.5 to 7.5 | ||||||
Recovery Rate % | 15 | ||||||
Operating Conditions | Max. Operating Pressure | 200psi (2.0Mpa) | |||||
Max. Feed Water Temp. | 45℃ | ||||||
Max. Feed Water Silt Density Index (SDI) | 5 | ||||||
Feed Water Chlorine Tolerance | < 0.1 mg/l | ||||||
Feed Water PH Range, Continuous Operation | 3 to 10 | ||||||
Feed Water PH Range, Short-Term Cleaning | 2 to 11 | ||||||
Max. Pressure Drop of Single Membrane | 10psi (0.07Mpa) |
NOTE: The produced water amount listed in the table is an average value, compared with the standard value, the difference of the minimum amount of water produced by a single membrane does not exceed ± 15%.
Model No. | Maximum Operating Temperature |
Maximum Operating Pressure |
Feed Water PH Range, continuous operation |
Maximum Feed Water Turbidity |
Maximum Feed Water SDI |
Chlorine Tolerance |
TFC-1812-50 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-1812-75 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-100 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-125 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-150 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
HID RO Membranes are widely used in ultra-pure water, process pure water, cooling tower water, boiler water supply, pure water, throughout the electronics industry, optoelectronic industry, machinery manufacturing, fine chemical industry, medical pharmaceutical, food, and beverage industry, surface coating, and many other industries.