Persisting in “High high quality, Prompt Delivery, Aggressive Price”, we’ve established long-term cooperation with clients from the two overseas and domestically and get new and old clients’ superior comments for Bw Brackish Water RO Industrial Membrane, 8040, Adhering into the business enterprise philosophy of ‘customer initial, forge ahead’, we sincerely welcome purchasers from at your home and abroad to cooperate with us.
Persisting in “High high quality, Prompt Delivery, Aggressive Price”, we’ve established long-term cooperation with clients from the two overseas and domestically and get new and old clients’ superior comments for Brackish Water Membrane, Industrial Membrane, Our company has already have pass the ISO standard and we’re fully respect our customer ‘s patents and copyrights. If the customer provides their own designs, We will guarantee that they might be the only one can have that merchandise. We hoping that with our good items can bring our customers a great fortune.
Being one of the earliest RO membranes manufacturers in China, HID TM ranks the best brands among the Chinese RO membrane industry. Each RO membrane is made of HID TM high rejection flat sheet and goes through most stringent manufacturing processes as well as in-house quality inspection & testing till delivery.
8040 series RO membranes are widely used for filtration of tap water, underground water & brackish water; we well serve the industries including commercial drinking/food water treatment, electronics & chemical works, power plants, etc.
- HID TM anti-fouling & high rejection flat sheet (film);
- lower energy costs (low pressure models) and higher productivity;
- highly stabilized rejection with realized nominal flux;
- minimize system CAPEX with HIDTM RO membrane excellent performance-price ratio;
- stringent in-house inspection & testing control.
Model No. | Feed Spacer thickness (mil) |
Min. Salt Rejection (%) |
Stabilized Salt Rejection (%) |
Permeate Flow Rate (GPD) |
Test Pressure (psi) |
Test water TDS (ppm) |
TW8-460ULP | 28 | 98.3 | 98.8 | 12000 | 150 | 1000 |
BW8-440XLE | 31 | 98.5 | 98.9 | 11000 | 150 | 1500 |
BW8-400LP | 31 | 98.6 | 99.2 | 10500 | 225 | 2000 |
BW8-380AF | 34 | 98.7 | 99.2 | 9600 | 225 | 2000 |
1. Permeate flow rate and salt rejection is based on testing conditions: 25℃, PH 7.5, 20% recovery.
2. Stabilized salt rejection is generally achieved within 24-48 hours of continuous use, depending upon feedwater characteristics and operating conditions.
Model No. | Maximum Operating Temperature |
Maximum Operating Pressure |
Feed Water PH Range, continuous operation |
Maximum Feed Water Turbidity |
Maximum Feed Water SDI |
Chlorine Tolerance |
TW8-460ULP | 45℃ | 600psi | 2-11 | 1NTU | 5 | <0.1ppm |
BW8-440XLE | 45℃ | 600psi | 2-11 | 1NTU | 5 | <0.1ppm |
BW8-400LP | 45℃ | 600psi | 2-11 | 1NTU | 5 | <0.1ppm |
BW8-380AF | 45℃ | 600psi | 2-11 | 1NTU | 5 | <0.1ppm |
To ensure proper startup of RO water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock.
To follow the proper startup procedure (available with water treatment system guide book) also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.
Before initiating system startup procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.
It is CRITICAL to avoid any abrupt pressure or cross-flow variations on the RO membrane elements during start-up, shutdown, cleaning or other sequences to prevent possible membrane damage. During startup, a gradual change from a standstill to operating state is recommended as follows:
• Feed pressure should be increased gradually over a 30-90 second time frame.
• Cross-flow velocity at set operating point should be achieved gradually over 15-30 seconds.
• Permeate obtained from the first hour of operation should be discarded.
Keep RO membrane elements moist at all times after initial wetting.
If operating limits and guidelines given in this specification are not strictly followed, the limited warranty with the supplier will be null and void.
To prevent biological growth during prolonged system shutdowns, it is recommended that RO membrane elements be immersed in a storage solution.
The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
The maximum pressure drop across an entire pressure vessel (housing) is 50 psi (3.4 bar).
Avoid static permeate-side backpressure at all times.
HID RO Membranes are widely used in ultra-pure water, process pure water, cooling tower water, boiler water supply, pure water, throughout the electronics industry, optoelectronic industry, machinery manufacturing, fine chemical industry, medical pharmaceutical, food, and beverage industry, surface coating, and many other industries.