We strive for excellence, services the customers”, hopes to be the top cooperation team and dominator business for personnel, suppliers and prospects, realizes benefit share and continual promotion for 75gpd Reverse Osmosis Membrane Water Treatment Equipment Parts, We sincerely welcome mates to negotiate organization and start cooperation. We hope to affix hands with good friends in different industries to produce a fantastic long term.
We strive for excellence, services the customers”, hopes to be the top cooperation team and dominator business for personnel, suppliers and prospects, realizes benefit share and continual promotion for 75gpd Reverse Osmosis Membrane, Water Treatment Equipment Parts Membrane, With the advanced workshop, professional design team and strict quality control system, based on mid- to high-end marked as our marketing positioning, our products are fast selling onto European and American markets with our own brands such as below Deniya, Qingsiya and Yisilanya.
HIDTM Residential Membrane ranks the best brands in China among the RO membrane industry. 75 GPD Reverse Osmosis (RO) Membrane has won the trust of thousands of families for feeding the reliable purified water over 10 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.
Model | TFC-1810-50 | TFC-1810-75 | TFC-1810-100 | TFC-2012-125 | TFC-2012-150 | TFC-2012- 200 | |
TFC-1812-50 | TFC-1812-75 | TFC-2012-100 | |||||
Perfor-mance | Stable Desalination % | 97 | 97 | 97 | 97 | 97 | 97 |
Min. Desalination % | 96 | 96 | 96 | 96 | 96 | 96 | |
Mean Permeable Flow GPD (L/d) | 50 (204) | 75 (281) | 100 (380) | 125 (478) | 150 (567.75) | 200(760) | |
Active Film Area ft2(m2) | 3.5 (0.32) | 4.2 (0.38) | 5.0 (0.46) | 5.0 (0.50) | 6.0 (0.8) | 10.33 (0.96) | |
Test Conditions | Pressure | 65psi (0.45Mpa) | |||||
Water Temp. | 25℃ | ||||||
Concentration(NaCl) | 500ppm | ||||||
Water PH | 6.5 to 7.5 | ||||||
Recovery Rate % | 15 | ||||||
Operating Conditions | Max. Operating Pressure | 200psi (2.0Mpa) | |||||
Max. Feed Water Temp. | 45℃ | ||||||
Max. Feed Water Silt Density Index (SDI) | 5 | ||||||
Feed Water Chlorine Tolerance | < 0.1 mg/l | ||||||
Feed Water PH Range, Continuous Operation | 3 to 10 | ||||||
Feed Water PH Range, Short-Term Cleaning | 2 to 11 | ||||||
Max. Pressure Drop of Single Membrane | 10psi (0.07Mpa) |
NOTE: The produced water amount listed in the table is an average value, compared with the standard value, the difference of the minimum amount of water produced by a single membrane does not exceed ± 15%.
Model No. | Maximum Operating Temperature |
Maximum Operating Pressure |
Feed Water PH Range, continuous operation |
Maximum Feed Water Turbidity |
Maximum Feed Water SDI |
Chlorine Tolerance |
TFC-1812-50 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-1812-75 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-100 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-125 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-150 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |