we could offer you premium quality items, competitive value, and best client provider. Our destination is “You come here with difficulty and we provide you with a smile to take away” for 100g RO Membrane, Our factory covers an area of 12,000 square meters, and has a staff of 200 people, among which there are 5 technical executives. We’ve been specialized in producing. Now we have rich experience in export. Welcome to contact us and your inquiry are going to be replied as soon as possible.
HIDTM Residential Membrane ranks the best brands in China among the RO membrane industry. Reverse Osmosis (RO) Membrane 100 GPD has won the trust of thousands of families for feeding the reliable purified water over 10 years. Each membrane is made of HID developed & pre-examined sheet and goes through stringent making processes as well as in-house quality inspection & testing before delivery. HID Membrane has been certified by SGS & China Jiangsu Sanitation Bureau wrt drinking water membrane elements.
Model | TFC-1810-50 | TFC-1810-75 | TFC-1810-100 | TFC-2012-125 | TFC-2012-150 | TFC-2012- 200 | |
TFC-1812-50 | TFC-1812-75 | TFC-2012-100 | |||||
Perfor-mance | Stable Desalination % | 97 | 97 | 97 | 97 | 97 | 97 |
Min. Desalination % | 96 | 96 | 96 | 96 | 96 | 96 | |
Mean Permeable Flow GPD (L/d) | 50 (204) | 75 (281) | 100 (380) | 125 (478) | 150 (567.75) | 200(760) | |
Active Film Area ft2(m2) | 3.5 (0.32) | 4.2 (0.38) | 5.0 (0.46) | 5.0 (0.50) | 6.0 (0.8) | 10.33 (0.96) | |
Test Conditions | Pressure | 65psi (0.45Mpa) | |||||
Water Temp. | 25℃ | ||||||
Concentration(NaCl) | 500ppm | ||||||
Water PH | 6.5 to 7.5 | ||||||
Recovery Rate % | 15 | ||||||
Operating Conditions | Max. Operating Pressure | 200psi (2.0Mpa) | |||||
Max. Feed Water Temp. | 45℃ | ||||||
Max. Feed Water Silt Density Index (SDI) | 5 | ||||||
Feed Water Chlorine Tolerance | < 0.1 mg/l | ||||||
Feed Water PH Range, Continuous Operation | 3 to 10 | ||||||
Feed Water PH Range, Short-Term Cleaning | 2 to 11 | ||||||
Max. Pressure Drop of Single Membrane | 10psi (0.07Mpa) |
NOTE: The produced water amount listed in the table is an average value, compared with the standard value, the difference of the minimum amount of water produced by a single membrane does not exceed ± 15%.
Model No. | Maximum Operating Temperature |
Maximum Operating Pressure |
Feed Water PH Range, continuous operation |
Maximum Feed Water Turbidity |
Maximum Feed Water SDI |
Chlorine Tolerance |
TFC-1812-50 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-1812-75 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-100 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-125 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-150 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |
TFC-2012-200 | 45℃ | 200psi | 4-11 | 1NTU | 5 | <0.1ppm |